Are You Allergic To Stitches (Sutures)?

This past week I was once again asked about suture allergy.  It has prompted me to revisit the issue which I have posted about twice now. (photo credit).

Sutures by their very nature of being foreign material will cause a reaction in the tissue.  This tissue reactivity is NOT necessarily a suture allergy.

Many factors may contribute to suture reactivity.

  • The length of time the sutures remain.  The longer the sutures are in, the more reactivity occurs.
  • The size of the sutures used.  The larger the caliber of the suture, the more reactivity.  The increase of one suture size results in a 2- to 3-fold increase in tissue reactivity.
  • The type of suture material used.  Synthetic or wire sutures are much less reactive than natural sutures (eg, silk, cotton, catgut).  Monofilament suture is less reactive than a braided suture.
  • The region of the body the suture is used affects tissue reactivity.  The chest, back, extremities, and sebaceous areas of the face are more reactive.

In general, accepted time intervals for superficial suture removal vary by body site, 5-7 days for the face and the neck, 7-10 days for the scalp, 7-14 days for the trunk, and 14 days for the extremities and the buttocks.  The deeper placed sutures will never be removed.

Sutures meant to dissolve (ie vicryl sutures) placed too high in the dermis (which happens often when the dermis is thin) can “spit” several weeks to several months after surgery. This is a reactive process, NOT a suture allergy.  It usually presents as a noninflammatory papule (looks very much like a pimple) and progresses with extrusion of the suture through the skin. The suture material may be trimmed or removed if loose, and it is not needed for maintaining wound strength.  Rarely does this affect the scar outcome.

The remaining portion is a “repost” about suture allergies:

Allergic reactions to suture materials are rare and have been specifically associated with chromic gut. However, Johnson and Johnson mention known triclosan allergy as a contraindication for use of certain sutures (see below). Contact allergy to triclosan is uncommon.

Surgical gut suture (Plain and Chromic) is contraindicated in patients with known sensitivities or allergies to collagen or chromium, as gut is a collagen based material, and chromic gut is treated with chromic salt solutions.

MONOCRYL Plus Antibacterial suture should not be used in patients with known allergic reactions to Irgacare MP(triclosan).

PDS Plus Antibacterial suture should not be used in patients with known allergic reactions to Irgacare MP (triclosan).

VICRYL*suture should not be used in patients with known allergic reactions to Irgacare MP (triclosan).  [In rechecking facts, I found that only Vicryl Plus has the triclosan, so simple vicryl or coated vicryl should be okay.]

Surgical Stainless Steel Suture may elicit an allergic response in patients with known sensitivities to 316L stainless steel, or constituent metals such as chromium and nickel. Skin staples are surgical steel so should be used with the same precautions.

Dermabond — Tissue glues should not be used in patients with a known hypersensitivity to cyanoacrylate or formaldehyde.

SO WHAT IS LEFT TO USE

So what is left to use in a patient who may have or has a proven allergy to suture or closure material?

Page 1 of 2 | Next page